CST MWS F求解器報(bào)錯 (TLM Solver)報(bào)錯
我在仿機(jī)箱屏蔽時(shí),在雙擊Frequency Domain后,求解器報(bào)錯 (TLM Solver) : wire "wire" partly inside metal ,沒有將頻域圖彈出來,請高手這個報(bào)錯什么意思?怎么處理???
信息窗口,謝謝!
(TLM Solver) : Counting wire nodes
(TLM Solver) : 42 cells contain wires
(TLM Solver) : Creating wire nodes
(TLM Solver) : 42 x-chains, 42 y-chains, 1 z-chains
(TLM Solver) : wire "wire" partly inside metal
(TLM Solver) : Error occurred at x: 49.295mm y: 250.325mm z: 1.25mm
(TLM Solver) : Location in model units x: 49.295 y: 250.325 z: 1.25
問題已解決,修改wire的長度,但是又有一個新問題 wire "wire" too fat for cell ,是說100 cells contain wires 太多了嗎?怎么改啊?我是新手,請教一下本站里的高手,謝謝\!
(TLM Solver) : 100 cells contain wires
(TLM Solver) : Creating wire nodes
(TLM Solver) : 100 x-chains, 100 y-chains, 1 z-chains
(TLM Solver) : 99 multiwire connects
(TLM Solver) : 0 multiwire to circuit connects
(TLM Solver) : 2 multiwire terminations
(TLM Solver) : wire "wire" too fat for cell
(TLM Solver) : Error occurred at x: 449.735mm y: 250.19mm z: 83.332um
(TLM Solver) : Location in model units x: 449.735 y: 250.19 z: 83.332m
上模型吧,這樣看不出來
謝謝了!在雙擊Frequency Domain后,求解器報(bào)錯 (TLM Solver) : wire "wire" too fat for cell 附件是模型
MARK 一下。
你的線纜的直徑太大 跟模型的網(wǎng)格有重疊部分 我在MS工作室遇到bundle of 2 wires too fat for cell這個問題,已經(jīng)解決了。你改變一下你的線纜路徑讓線纜不要跟模型有重疊部分。MS工作室?guī)椭募锞€纜和電路部分有這部分內(nèi)容Wires and Circuits