CST Studio Suite 2010 Service Pack 5 Released (2010-07-19)
Service Pack 2010.05
General / Environment
Fixed a problem in getting port mode type via ResultReader.dll
Macros
New Macro for optical applications: Macros - Solver - Generate Gaussian Beam as Field Source New Feature!
New Macro for EDA imported structures: Macros - Construct - Vias - Create Plated Vias from EDA Import New Feature!
New Macro for robust surface meshing: Macros - File - Prepare SAT file for robust surface meshing New Feature!
New Macro to construct parametric radial stubs: Macros - Construct - Radial Stub New Feature!
New 1D Result template for broadband Port Properties New Feature!
Modeler / Structure Visualization / Imports
The nastran-import with option "read points only" now preserves the ordering of the points as in the nastran-file
Fixed a problem with picking edges by coordinates
'Use step width and extend range' of local mesh properties is now transferred with subproject imports.
Fixed vector component selection for interactive evaluate field along curve
Improved display of nonstandard characters in the job control center
Improved handling of tube-like face ports
Post Processing
Fixed issue with farfield source phase visualization
Fixed handling of balance in combination with renormalization during TOUCHSTONE export
Array directivity normalization improved
Fixed an issue in template based postprocessing of farfields when the corresponding project is not activated
Tetrahedral (Tet) Mesh
Added a switch to enable/disable the selfintersection check. New Feature!
Fixed a problem for models with many material conflicts
EDA Imports
Fixed some issues when importing geometry with overlapping nets
Added option to determine a missing via diameter from the smallest available pad diameter New Feature!
Distributed Computing (DC)
Fixed a problem while DC main controller is waiting for next send slot
Fixed a problem with hanging solver servers
CST MICROWAVE STUDIO - Transient Solver
Verified TCC driver for GPU computing on Server 2008 R2 New Feature!
Fixed some issues in MPI cluster compuing setup
Fixed some issues in calculation of translated farfields
CST MICROWAVE STUDIO - Frequency Domain (FD) Solvers
Probe results of the frequency domain solver with tetrahedral mesh were not visible with discrete port excitation
Made the phase of the discrete edge port excitation of the frequency domain solver with tetrahedral mesh consistent with the time domain solver
In two-conductor-systems with large inner conductor and small ground, the automatic detection of the inner conductor now is consistent with the time domain solver
The port mode solver of the frequency domain solver with tetrahedral mesh ignores losses for single ended waveguide ports
Fixed inaccuracy in calculation of material sensitivity parameters
Fixed an issue with the phase of a unit cell farfield array factor
CST MICROWAVE STUDIO - Asymptotic Solver
Fixed problem in writing result data for a particular model
CST CABLE STUDIO
Fixed some issues with special characters in file paths
CST PCB STUDIO
Fixed a problem when importing a PADS file
CST DESIGN STUDIO
Resolved a problem with continuous approximation of switch hysteresis curve
Fixed issue in simulation of multiple SPICE sources
版主用SP5有沒有發(fā)現(xiàn)什么bug啊。我怎么覺得用的很不順手呢。
最近沒有什么仿真的任務,所以沒什么可分享的。
你覺得不順手的原因是什么?
以前仿真從來沒有死機過。這次在做一個天線遠場的時候,竟然死機了。
據(jù)說這次更新主要是對于天線的,是做手機天線人的福音啊,不過暫時我還沒用到。
如果真的是SP的問題的話,CST客服現(xiàn)在就該炸了鍋了……。再多試幾次,看看是不是重復出現(xiàn),有沒有規(guī)律性。
從更新內容好象看不出來是針對天線開發(fā)的,應該就是例行的軟件升級。