這些ERROR怎么解?
學(xué)習(xí)CST中遇到了很多ERROR不知道怎么個意思,還有怎么個解法.誰能幫解釋下
虛心向高人學(xué)習(xí),謝謝!
1. The port mode Eigensolver(本征求解器) failed because the maximum number
of iterations has been reached.
2. Single-ended definition requires a separate mode set for each pin
.Please check waveguide Port Number.
3. The propagation constant of mode1 is zero ,cannot continue.
4. Waveguide for port nuber 1 is too short. The waveguide must be
homogeneous for at least three mesh planes along propagation direction.
5. Too few conductors detected .Conductors might be short-circuited in
port plane.
6. On port 2 multiple potential definitions of the same set are located on one conductor ,or a symmetry condition is incompatible with the potential definitions.
4. Waveguide for port nuber 1 is too short. The waveguide must be
homogeneous for at least three mesh planes along propagation direction.
需要局部加密,選中靠近端口的組件,右鍵->local mesh properties->在XYZ方向上加密,直到你那個組件離端口最近的那部分加密到三個網(wǎng)格即可。
您遇到的問題主要都是波導(dǎo)端口的定義和端口處網(wǎng)格的定義上,答案如下。希望幫得上你。
1、這個提示并不是真正的本征模求解器的問題。CST的2008版以后的版本中對波導(dǎo)端口的求解精度進行了提高,每次進行仿真的時候,會自動對波導(dǎo)端口進行自適應(yīng)網(wǎng)格收斂性分析,并得到精確的結(jié)果。這里出現(xiàn)這樣的錯誤提示:主要是波導(dǎo)端口處的起始網(wǎng)格設(shè)置太粗,經(jīng)過了4次(缺省值)網(wǎng)格迭代后仍不能達到指定的1%(缺省值)的精度要求,所以計算停止了。解決方法:提高端口處的起始網(wǎng)格或者取消自適應(yīng)分析,更建議用前者。
2、要進行單端S參量計算,是要定義多芯端口的。CST叢書3中有多芯端口定義的詳細介紹,老兄可以買來看看。也不貴!
3、真不知道您是怎樣定義的波導(dǎo)端口,波導(dǎo)端口的傳播常數(shù)為0啊,這當(dāng)然不能繼續(xù)進行下去了。
4、還是波導(dǎo)端口的問題,波導(dǎo)端口的定義要求端口面處,傳播方向上至少要有3個網(wǎng)格才行的。
5、同樣,斷口處的網(wǎng)格太少,端口面上都短路了。
6、多芯端口定義的不對,這個錯誤說明您把多個電勢定義到同一根內(nèi)導(dǎo)體上了。這怎么行!建議你看看叢書3或者他們有本叢書9里面有個多層差分線的例子介紹的也挺好。
來自微波技術(shù)網(wǎng)的高手的回答,以后有問題也可以去那兒發(fā)。
http://imw.mwhrf.com/viewthread.php?tid=16910&pid=120978&page=1&extra=page%3D1
非常感謝..........